Cooling Tower PVC Fills Specification

  • Application
  • cooling tower
  • Material
  • PVC
  • Condition
  • New
  • Usage
  • Industrial
  • Size
  • Different Sizes Available
  • Dimension (L*W*H)
  • 600 x300 x 150 Millimeter (mm)
  • Product Type
  • INDUSTRIAL
  • Voltage
  • 220-440 Volt (v)
  • Color
  • Black or Blue
  • Warranty
 

Cooling Tower PVC Fills Trade Information

  • Minimum Order Quantity
  • 10 Number
  • FOB Port
  • CHENNAI
  • Payment Terms
  • Telegraphic Transfer (T/T)
  • Supply Ability
  • 1 Number Per Week
  • Delivery Time
  • 4 Days
  • Sample Available
  • Yes
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • MSME
 

About Cooling Tower PVC Fills

Virgin and reprocessed PVC-made Film Fills are cooling Tower Components. These are accessible in 1200 mm x 600 mm , 600 mm x 600 mm and 600 mm x 300 mm size choices. The longitudinal pitch of these fills is 37.5 mm and their flute height is 12 mm. The standard weight of these Film Fills is 29.5 kg/m3. Per unit volume of their surface area is 258 m2/m3. The maximum continuous operating temperature of these components is 55 degree C. Minimum sheet thickness of such fills is 0.200 mm. Standard of these cooling tower components has been checked on the basis of their service life, diameter, utility etc.

Characteristics

CD-12

Primary Cooling Towers Application

Counterflow

Flute height

12 mm

MOC

Rigid PVC (Virgin and reprocessed)

Longitudinal pitch

37.5 mm

UV Stabilization

White Titanium Dioxide
Black Carbon Black

Blue

Spiral angle

28

Std. Sheet size L x W

600mm x 300mm

Recommended Max Fill Sheet size L x W

1200 mm x 600 mm

Surface area per unit volume

258 m/m

Standard Weight

29.5 Kgs/m3

Maximum continuous Operating temp.

55 C

Minimum Fill Sheet Finished Thickness

0.200 mm

Standard Followed for Material properties

CTI STD-136

Gold Cooling Towers.

114, P.K.D.Nagar,2nd Street,

Peelamedu,Coimbatore - 641 004.

Tamil Nadu.INDIA.

E-Mail:-goldct@ymail.com,rameshpv2011@gmail.com

M +917010548608 , 9626963255 ,

www.goldcoolingtowers.com

GST No: 33AIIPV1052H1ZC , IE Code no:3214031198



Reliable Cooling Performance

Our PVC fills are engineered to maximize surface area, improving water and air contact within the cooling tower. This leads to improved heat transfer efficiency and reduces the operational costs of industrial cooling systems. These fills help maintain consistent cooling tower performance, making them indispensable for many heavy-duty applications.


Versatile Sizing & Application

We offer different sizes, including the standard 600 x 300 x 150 mm dimension, to suit various cooling tower designs. These PVC fills are suitable for replacement and new installations across diverse industrial environments. Our customization capabilities allow us to meet your specific cooling needs, ensuring seamless integration with your existing systems.

FAQs of Cooling Tower PVC Fills:


Q: How are Cooling Tower PVC Fills installed in industrial cooling towers?

A: Cooling Tower PVC Fills are generally installed by placing them within the fill section of the cooling tower. Their modular design allows for easy stacking and fitting, ensuring optimal water distribution and heat exchange during operation.

Q: What advantages do PVC fills offer over other fill materials for cooling towers?

A: PVC fills provide excellent resistance to corrosion, offer superior heat transfer efficiency, and are lightweight, making installation easier. Their durability ensures a longer lifespan and lower maintenance requirements in industrial environments.

Q: When should Cooling Tower PVC Fills be replaced or serviced?

A: It is advisable to inspect and, if necessary, replace PVC fills during regular cooling tower maintenance cycles. Replacement is recommended if there is significant clogging, physical damage, or diminished cooling efficiency.

Q: Where can I source new Cooling Tower PVC Fills in India?

A: As a leading manufacturer, service provider, and supplier in India, we offer new Cooling Tower PVC Fills suitable for a range of industrial applications. Please contact our sales team for inquiries and orders.

Q: What is the typical process for manufacturing these PVC fills?

A: Our PVC fills are manufactured using high-grade PVC sheets that are thermoformed or vacuum-formed into structured fill packs. These are then trimmed and assembled to precise dimensions, ensuring uniform performance in cooling towers.

Q: How do PVC fills improve the efficiency of cooling tower systems?

A: By increasing the surface area for water-air contact within the tower, PVC fills enhance heat exchange and promote better cooling. This results in reduced energy consumption and more consistent cooling for industrial processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cooling Tower Spare Parts Category

Electric Cooling Tower Motors

Electric Cooling Tower Motors

Price 5500 INR / Unit

Minimum Order Quantity : 1 Number

Application : Industrial Cooling Towers

Condition : New

Dimension (L*W*H) : Standard and Custom Sizes Available

Cooling Tower Spare Parts

Cooling Tower Spare Parts

Price 175 INR / Set

Minimum Order Quantity : 10 Sets

Application : COOLING TOWER

Size : Different Sizes Available

Sigma Cross Flow Cooling Tower Fills

Sigma Cross Flow Cooling Tower Fills

Minimum Order Quantity : 100 Sheets

Condition : New

Size : Different Sizes Available

Wooden Cooling Tower With Jali

Wooden Cooling Tower With Jali

Price 10000 INR / Unit

Minimum Order Quantity : 1 Unit

Application : wooden Timber cooling tower

Condition : New

Dimension (L*W*H) : 8x38x1220 Millimeter (mm)



"We mainly deals in Andhra Pradesh, Goa, Karnataka, Tamil Nadu, Kerala, Maharashtra, Puducherry, Odisha, Telangana only".
Back to top